The numbers below refer to the step numbers on the diagnostic table.
Mode Position | Value |
---|---|
Defrost | 0 Counts |
Mix-Blend | 65 Counts |
Floor | 110 Counts |
Bi-Level | 220 Counts |
Vent | 255 Counts |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the blower motor switch in each speed position. Does the blower motor operate in each speed position? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the blower motor operate at the desired speeds? | Go to Step 5 | Go to Blower Motor Malfunction |
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | Go to Step 6 | |
6 |
Does the scan tool display any DTCs? | Go to Step 7 | |
7 | Place the mode switch in each mode position. Does the air flow from the correct air distribution outlets in each selected mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 8 |
8 |
Does the scan tool display the correct state for each selected mode? | Go to Step 9 | Go to Step 10 |
Does the scan tool indicate that the Htr./Def./A/C Dr. Commanded parameter is near the specified value in each mode position? Refer to the test description for this step. | Go to Step 11 | Go to Step 10 | |
10 | Inspect for poor connections at the harness connector of the HVAC control module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
11 | Inspect and the air distribution system for the following conditions:
Did you find and correct the condition? | Go to Step 13 | -- |
12 |
Important: Perform the recalibration procedure for the IPM. Replace the IPM. Refer to HVAC Control Module Replacement . Did you complete the replacement? | Go to Step 13 | -- |
13 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |