Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was Instrument Cluster System Check performed? | -- | Go to Step 2 | |
2 |
Does average fuel reset to zero ? | -- | Go to Step 3 | |
3 |
Does the INFO Reset Switch input toggle from ON to OFF when button is pressed? | -- | Go to Step 11 | Go to Step 4 |
4 | Does the INFO up button work? | -- | Go to Step 5 | Go to Step 8 |
5 |
When the jumper is added and removed does the scan tool INFO RESET toggle to off ? | -- | Go to Step 10 | Go to Step 6 |
6 | Check for CKT 1816 (ORN) for an open or short to ground. Was there a problem with CKT 1816? | -- | Go to Step 7 | Go to Step 11 |
7 | Repair CKT 1816 (ORN). Is the repair complete? | -- | -- | |
8 | Check for CKT 451 (BLK/WHT) for an open. Was there a problem with CKT 451? | -- | Go to Step 9 | Go to Step 10 |
9 | Repair CKT 451 (BLK/WHT). Is the repair complete? | -- | -- | |
10 | Replace the RH IPC control (DIC) switch. Refer to Driver Information Display Switch Replacement . Is the repair complete? | -- | -- | |
11 | Replace the Instrument Cluster (IPC). Refer to Instrument Cluster Replacement . Is the Instrument Cluster (IPC) replacement complete? | -- | -- |