• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ambient Light Sensor Signal | B2646 | B2646 | B2646 | -- |
Driver Sun Load Sensor Signal | B0184 | B0184 | B0184 | -- |
Passenger Sun Load Sensor Signal | B0189 | B0189 | B0189 | -- |
Sunload Sensor Assembly Low Reference | -- | B0184, B0189, 2 | B0184, B0189, 2 | -- |
Left Front Turn Signal Lamp Supply Voltage | B3948 02 | B3948 05 | B3948 05 | -- |
Right Front Turn Signal Lamp Supply Voltage | B3949 02 | B3949 05 | B3949 05 | -- |
Turn Signal Lamp - LF Ground | -- | 1 | 1 | -- |
Turn Signal Lamp - RF Ground | -- | 1 | 1 | -- |
1. Turn Signal Lamps and/or Indicators Malfunction 2. Daytime Running Lamps (DRL) Inoperative |
The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 volts depending on outside lighting conditions. The HVAC control module provides a low reference ground and a 5-volt reference signals to the ambient light sensor. The HVAC control module monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. The HVAC control module sends a signal to the body control module (BCM) via class 2 serial data commanding the BCM to turn the front turn signal lamps on steady (non-flashing). Any function or condition that turns on the headlamps will cancel the DRL operation. With the turn signal/multifunction switch in the OFF position, the turn signal lamps will either be turned ON or OFF after a 30-second delay, depending on whether daylight or low light conditions are sensed by the ambient light sensor.
Important: This diagnostic procedure assumes that the turn signal lamps are operating within specifications. If the turns signal lamps are inoperative, diagnose the turn signal malfunction before proceeding with the following diagnostic. Refer to Turn Signal Lamps and/or Indicators Malfunction .
Headlights/Daytime Running Lights (DRL) Schematics
Lighting Systems Connector End Views
Ignition ON, verify with a scan tool the park brake switch parameter displays RELEASED.
⇒ | If not the specified value, refer to Symptoms -- Hydraulic Brakes. |
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If the scan tool displays NIGHT, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM or HVAC control module replacement, setup, and programming |