• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Folding Top Control Module Battery Voltage | 1 | 1 | -- | -- |
Folding Top Control Module Control | B1420 | B1420 | -- | -- |
Folding Top Control Module Ground | -- | 1, 2 | -- | -- |
Folding Top Control Switch Battery Voltage | 2 | 2 | -- | -- |
Folding Top Control Switch Close Signal | 2 | 2 | B3602 | -- |
Folding Top Control Switch Open Signal | 2 | 2 | B3602 | -- |
Front Panel Position Sensor 5-Volt Reference | B3665, B3666, B3971 | B3665 | B3665, B3666, B3670, B3971 | -- |
Front Panel Position Sensor Signal | B3665 | B3665 | B3665 | -- |
Front Panel Position Sensor Low Reference | -- | B3665 | -- | -- |
Folding Top Position Sensor 5-Volt Reference | B3665, B3666, B3971 | B3971 | B3665, B3666, B3670, B3971 | -- |
Folding Top Position Sensor Signal | B3971 | B3971 | B3971 | -- |
Folding Top Position Sensor Low Reference | -- | B3971 | -- | -- |
Rear Panel Position Sensor 5-Volt Reference | B3665, B3666, B3971 | B3666 | B3665, B3666, B3670, B3971 | -- |
Rear Panel Position Sensor Signal | B3666 | B3666 | B3666 | -- |
Rear Panel Position Sensor Low Reference | -- | B3666 | -- | -- |
Folding Top Pump Motor Temperature Sensor 5-Volt Reference | B3665, B3666, B3971 | 2, 7 | B3665, B3666, B3670, B3971 | -- |
Folding Top Pump Motor Temperature Sensor Signal | 2, 7 | 2, 7 | B3670 | -- |
Hard Top Connected Signal | B1420 | 4, 7 | B1310 | -- |
Folding Top Closed Switch Control | B1420 | 4, 7 | -- | -- |
Front Latched Position Switch Signal | B1420, 3, 4, 7 | 3, 4, 7 | B1300 | -- |
Front Latched Position Switch Control | B1420 | 3, 4, 7 | -- | -- |
Front Unlatched Position Switch Signal | B1420, 9 | 9 | B1300 | -- |
Front Unlatched Position Switch Control | B1420 | 9 | -- | -- |
Compartment Partition Position Switch Signal | B1420, 2, 7 | 2, 7 | 8 | -- |
Compartment Partition Position Switch Control | B1420 | 2, 7 | -- | -- |
Pump Direction A Control | B1011 | 2 | -- | -- |
Pump Direction B Control | B1011 | 2 | -- | -- |
Rear Compartment Lid Open Switch Signal | B1420, 3, 4 | 3, 4 | B3669 | -- |
Rear Compartment Lid Open Switch Control | B1420 | 3, 4 | -- | -- |
Folding Top Valve 1 Control | 1 | 3 | -- | -- |
Folding Top Valve 1 - Ground | -- | 3 | -- | -- |
Folding Top Valve 2 Control | 1 | 4 | -- | -- |
Folding Top Valve 2 - Ground | -- | 4 | -- | -- |
Folding Top Valve 3 Control | 1 | 3, 4, 6 | -- | -- |
Folding Top Valve 3 - Ground | -- | 3, 4, 6 | -- | -- |
Folding Top Valve 4 Control | 1 | B1297, 3, 4, 5 | -- | -- |
Folding Top Valve 4 - Ground | -- | B1297, 3, 4, 5 | -- | -- |
Folding Top Valve 5 Control | 1 | 2 | -- | -- |
Folding Top Valve 5 - Ground | -- | 2 | -- | -- |
1. No communication with the FTC module 2. Power folding top is inoperative 3. Power folding top does not open or complete the top opening procedure 4. Power folding top does not close or complete the top closing procedure 5. Rear Compartment lid will not open 6. Rear compartment lid will not close 7. DIC warning message displayed 8. Folding top will operate with the rear compartment partition removed 9. No effect on power folding top operation |
The power folding top system uses seven different position or limit switches and three position sensors that provide input information to the folding top control (FTC) module. The FTC module uses this input information to determine the state and position of the folding top components. Then based on these inputs, the module applies battery voltage to the appropriate control circuits to the folding top pump motor and the appropriate valves in order to control the hydraulic system used to operate the folding top.
• | Complete the check list, prior to performing the diagnosis: |
- | When the folding top control switch is pressed, check for driver information center (DIC) warning messages. |
- | Windows are normalized. Refer to Power Window Reinitialization. |
- | Compartment partition is installed and secured, closing the compartment partition position switch. |
- | Vehicle is in PARK. |
- | Press the ignition to ACCY or RUN, with the engine OFF. |
- | Hydraulic fluid bypass valve in the operating position, turned clockwise, located above the pump motor. |
- | Operating temperature is normal. |
• | Whenever the open/close control switch is released or the top becomes inoperative in a suspended state, pressure will be maintained in the hydraulic system to avoid drifting and damage of components. After 4 minutes, the FTC module will gradually release the hydraulic pressure allowing the top to gradually settle to a resting position. |
• | When using the scan tool, the Rear Compartment Lid is referenced as the Deck Lid. |
• | If a repair is made to a signal circuit for a short to ground, test the component of that circuit for proper operation. |
• | Using the scan tool to access the History parameters for the folding top control (FTC) module, will display the last status of the items listed. |
Power Folding Top Description and Operation
Control Module References for Scan Tool Information
⇒ | If the DIC displays Close Cargo Divider, refer to the Compartment Partition Switch Test. |
⇒ | If the DIC displays Top Inop-Valet On, refer to the Valet Switch Test. |
⇒ | If the DIC displays Too Cold to Move Top, refer to the Thermal Sensor Test. |
⇒ | If the top attempts to open then stops, refer to Power Folding Top Does Not Open. |
⇒ | If the top attempts to close then stops, refer to Power Folding Top Does Not Close. |
⇒ | If not the specified values, refer to the Folding Top Control Switch Test. |
⇒ | If not the specified value, refer to Power Windows Description and Operation. |
⇒ | If not the specified value, refer to Power Windows Description and Operation. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal B for a short to voltage. If the circuit tests normal, replace the FTC module. |
⇒ | If not the specified value, test the signal circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the HVAC control module. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the FTC module. |
⇒ | If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the FTC module. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If not the specified value, test the signal circuits terminal 1 and terminal 2 for a short to voltage. If the circuits test normal, replace the FTC module. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the folding top control module. |
⇒ | If not the specified value, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the folding top control module. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp remains OFF during either of the commands, test the control circuits for a short to ground or an open/high resistance. If the circuits test normal, replace the FTC module. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FTC module. |
⇒ | If not the specified value, replace the folding top control switch. |
⇒ | If not the specified value, replace the folding top control switch. |
⇒ | If not the specified value, replace the folding top control switch. |
⇒ | If not the specified value, replace the folding top control switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Important: Perform the Power Folding Top Learn after component replacement.
• | Control Module References for FTC module and HVAC control module replacement, setup, and programming |