Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Interior Lamps System Check? | -- | Go to Step 2 | |||||||||
2 |
Do the lamps turn OFF within the specified time? | 40 seconds | Go to Step 3 | |||||||||
3 | Disconnect the headlamp and panel dimmer switch. Do the lamps remain On without the remote control door lock receiver? | -- | Go to Step 4 | Go to Step 5 | ||||||||
4 |
Is there continuity? | -- | Go to Step 17 | Go to Step 18 | ||||||||
5 | Do the lamps remain ON with the remote control door lock receiver? | -- | Go to Step 6 | Go to Step 7 | ||||||||
6 |
Is there continuity? | -- | Go to Step 13 | Go to Step 14 | ||||||||
7 | Do all of the lamps turn OFF? | -- | Go to Step 8 | Go to Step 3 | ||||||||
8 |
Do the lamps remain ON? | -- | Go to Step 9 | Go to Step 10 | ||||||||
9 | Replace the headlamp and panel dimmer switch? Headlamp Switch Replacement Is the replacement complete? | -- | -- | |||||||||
10 |
Do the lamps remain ON after all of the door jamb switches are disconnected? | -- | Go to Step 12 | Go to Step 11 | ||||||||
11 | Replace the affected door jamb switch. Refer to Door Jamb Switch Replacement in Doors. Is the replacement complete? | -- | -- | |||||||||
12 | Disconnect the door lock control module. Do the lamps remain ON? | -- | Go to Step 19 | Go to Step 20 | ||||||||
13 | Repair the short to ground in CKT 157 (GRY) between the remote control door lock receiver and the headlamp and panel dimmer switch. Is the repair complete? | -- | -- | |||||||||
14 | Connect a DMMJ 39200 from CKT 156 (WHT) cavity S to the remote control door lock receiver connector to ground. Is there continuity? | -- | Go to Step 15 | Go to Step 16 | ||||||||
15 | Repair the short to ground in CKT 156 (WHT) between the following components:
Is the repair complete? | -- | -- | |||||||||
16 | Replace the remote control door lock receiver. Refer to Receiver Replacement in Keyless Entry. Is the replacement complete? | -- | -- | |||||||||
17 | Repair the short to ground in CKT 157 (GRY) between the interior lamp control module and the headlamp and panel dimmer switch. Is the repair complete? | -- | -- | |||||||||
18 | Connect a DMMJ 39200 from CKT 156 (WHT) cavity E to the interior lamp control module connector to ground. Is there continuity? | -- | Go to Step 23 | Go to Step 24 | ||||||||
19 | Repair the short to ground in CKT 328 (PPL) between the following components:
Is the repair complete? | -- | -- | |||||||||
20 | Connect a Digital Multimeter from CKT 1897 (ORN/BLK) at the door lock control module connector cavity F to ground. Is there continuity? | -- | Go to Step 21 | Go to Step 22 | ||||||||
21 | Repair the open in CKT 1897 (ORN/BLK) between the door lock control module and the side door jamb switch. Is the repair complete? | -- | -- | |||||||||
22 | Replace the door lock control module. Is the replacement complete? | -- | -- | |||||||||
23 | Repair the short to ground in CKT 156 (WHT) between the following components:
Is the repair complete? | -- | -- | |||||||||
24 | Replace the interior lamp control module. Refer to Interior Lamp Control Module Replacement . Is the replacement complete? | -- | -- |