The numbers below refer to the step numbers on the diagnostic table.
Checks for proper operation of the coolant bypass valve.
The specified values are from the A/C System Performance Test.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Auxiliary air temperature can not be adjusted from one or both auxiliary controls or auxiliary cooling is insufficient. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Important: The auxiliary A/C system cannot request A/C compressor operation. The mode switch must be positioned to MAX, NORM, BI-LEVEL, BLEND or DEFROST on the HVAC control module to provide cooled airflow through the auxiliary system. Does the HVAC control module operate and provide sufficient cooling? | Go to Step 3 | Go to Too Hot in Vehicle |
3 |
Does the auxiliary blower motor operate at all? | Go to Step 4 | |
4 | Does the auxiliary blower motor operate correctly for each speed position? | Go to Step 5 | |
5 | Is the vehicle equipped with an auxiliary heating system? | Go to Step 6 | Go to Step 7 |
Are the auxiliary heater hoses or auxiliary heater core hot? | Go to Step 8 | Go to Step 7 | |
Perform the refrigerant system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition? | Go to Step 15 | Go to Step 8 | |
8 | Disconnect the vacuum hose from the auxiliary coolant bypass valve. Is there vacuum present at the auxiliary coolant bypass valve vacuum hose? | Go to Step 9 | Go to Step 11 |
9 |
Does the test lamp illuminate? | Go to Step 10 | Go to Step 11 |
10 | Test the heater water control solenoid control circuit of the coolant bypass valve solenoid for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 12 |
11 | Inspect for poor connections at the harness connector of the coolant bypass valve solenoid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 13 |
12 | Inspect for poor connections at the harness connector of the auxiliary heater blower motor switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 15 | Go to Step 14 |
13 | Replace the auxiliary coolant bypass valve. Refer to Coolant Bypass Valve Replacement - Auxiliary in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 15 | -- |
14 | Replace the auxiliary heater blower motor switch. Refer to Heater Control Blower Switch Replacement . Did you complete the replacement? | Go to Step 15 | -- |
15 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |