Important: Warmer engine or ambient temperature decreases the refrigerant recovery
time during the A/C flush procedure.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging
.
- Remove the orifice tube. Refer to
Expansion (Orifice) Tube Replacement
.
- Connect the A/C lines with the orifice tube removed.
- Remove the A/C compressor. Refer to
Air Conditioning Compressor Replacement
.
- Install the J 45268-3 to the A/C compressor hose
assembly.
- Forward flow refrigerant
flushing is recommended for contaminated refrigerant or PAG oil.
Perform the following procedure:
| Important: The filter inside the J 45268-1 is serviceable. Remove
and discard the check valve from the filter.
|
6.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect the J 45268-1 flush filter to the suction port
of the J 45268-3 flush adapter.
6.2. | Connect the blue hose from the J 43600
to the J 45268-1 flush filter adapter. |
6.3. | Connect the red hose from the J 43600
to the J 45268-3. |
- Reverse flow refrigerant flushing is recommended for desiccant
bag failure only.
Perform the following procedure and replace
the accumulator when the flush is complete:
| Important: The filter inside the J 45268-1 is serviceable. Remove
and discard the check valve from the filter.
|
7.1. | Service the filter with ACDelco P/N GF 470, before each flush. |
Connect the J 45268-1 flush filter to the discharge port
of the J 45268 --3 flush adapter.
7.2. | Connect the blue hose from the J 43600
to the J 45268-1 flush filter adapter. |
7.3. | Connect the red hose from the J 43600
to the suction port of the J 45268-3. |
- Flush the A/C system. Follow the instructions supplied with the J 43600
.
Close
the valve on the external refrigerant tank, before starting the flush process.
- Remove the J 45268-3 from the A/C compressor hose
assembly.
• | Remove the A/C compressor drain plug. |
• | Drain the PAG oil from the A/C compressor. |
• | Rotate
the compressor input shaft to assist in draining the PAG oil from the compressor. |
• | Install the A/C compressor drain plug. |
Tighten
Tighten the drain plug to 20N·m (15 lb ft).
- Install the A/C compressor. Refer to
Air Conditioning Compressor Replacement
.
- Inspect the orifice tube for debris.
Clean or replace
as needed.
- Install the orifice tube. Refer to
Expansion (Orifice) Tube Replacement
.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
Important: Flushing will remove all the PAG oil from the A/C system.
- Add the total system capacity of PAG oil to the A/C system. Refer to
Refrigerant System Capacities
.
Important: Flushing will remove the fluorescent leak detection dye from the A/C
system.
- Add one bottle of J 41447
using the J 41459
.
- Leak test the fittings using the J 42220
.