Removal Procedure
- Remove the front left fender. Refer to
Front Fender Replacement - Left Side
.
- Remove the coolant recovery reservoir. Refer to
Coolant Recovery Reservoir Replacement
.
- Remove the electrical connectors as necessary.
Important: Cut as straight as possible as the access cover must be replaced and
part of this repair is visible to the customer.
- Cut through the cover on the cut line with a razor blade or a sharp
utility knife.
- Remove the access cover screws.
- Remove the cooling tube.
- Remove the wiring harness from the blower motor assembly.
- Remove the blower motor assembly.
Installation Procedure
- Install the blower motor
assembly.
- Install the wiring harness to the blower motor assembly.
- Install the cooling tube.
- Install the access cover.
- Install the blower motor access cover retaining screws.
- Install the coolant reservoir. Refer to
Coolant Recovery Reservoir Replacement
in Engine Cooling.
- Install the electrical connectors as necessary.
- Install the front left fender. Refer to
Front Fender Replacement - Left Side
.