GM Service Manual Online
For 1990-2009 cars only

Step

Action

Yes

No

1

  1. Start the engine.
  2. Turn the blower motor fan ON and select an air outlet mode.

Does air flow out of the selected HVAC outlet ducts?

Go to Step 3

Go to Step 2

2

Did the customer concern mention that the air discharges out the correct ducts at first, but then changes during higher engine RPM?

Go to Step 7

Go to Step 3

3

With the engine running, cycle the HVAC controls through all the modes.

Does the air come out of the selected outlet ducts?

Go to Step 18

Go to Step 4

4

With the engine running, take a vacuum reading at the manifold vacuum port that supplies vacuum to the HVAC vacuum control assembly.

Is there engine vacuum?

Go to Step 6

Go to Step 5

5

Repair the no vacuum condition.

Is the repair complete?

Go to Step 18

--

6

Take a vacuum reading at the vacuum supply line at the HVAC vacuum control assembly.

Is the vacuum reading the same as the engine vacuum?

Go to Step 11

Go to Step 8

7

  1. Disconnect the vacuum supply line from the HVAC vacuum control assembly.
  2. With the vacuum gauge connected to the vacuum supply line, re-start the engine and turn the engine OFF.

Does the system lose vacuum after turning OFF the engine?

Go to Step 8

Go to Step 11

8

Inspect for leaking or collapsed vacuum lines between the engine manifold vacuum port and the HVAC vacuum control assembly.

Are the vacuum lines leaking?

Go to Step 9

Go to Step 10

9

Repair or replace the collapsed or leaking vacuum line.

Is the repair complete?

Go to Step 18

--

10

Replace the vacuum reservoir tank. Refer to Vacuum Tank Replacement .

Is the repair complete?

Go to Step 18

--

11

Using an external vacuum source, apply vacuum to the appropriate vacuum line at the connector to the HVAC vacuum control assembly. Refer to HVAC Schematics .

Does the actuator retract?

Go to Step 17

Go to Step 12

12

Inspect for leaking or collapsed vacuum lines between the actuator and the connector to the HVAC vacuum control assembly.

Are the vacuum lines leaking?

Go to Step 9

Go to Step 13

13

  1. Disconnect the vacuum line from the actuator.
  2. Apply an external vacuum source to the actuator.

Did the actuator retract?

Go to Step 14

Go to Step 16

14

With the actuator disconnected, inspect the door for binding.

Does the door move freely?

Go to Step 16

Go to Step 15

15

Repair the binding door. Refer to the appropriate repair.

    •  Mode Door Replacement

Is the repair complete?

Go to Step 18

--

16

Replace the vacuum actuator. Refer to the appropriate repair.

Is the repair complete?

Go to Step 18

--

17

Replace the HVAC vacuum control assembly. Refer to Heater and Air Conditioning Control Replacement .

Is the repair complete?

Go to Step 18

--

18

Cycle the HVAC controls through all modes to verify proper operation.

Did you correct the condition?

System OK

--