The numbers below refer to the step numbers on the diagnostic table.
The ambient air temperature must be above 3°C (38°F) for this A/C compressor test.
The specified values are from the A/C System Performance Test.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics. Connector End View Reference: Component Connector End Views. DEFINITION: The temperature cannot be adjusted, or cooling is insufficient during A/C operation. | ||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |
2 |
Important: All DTCs that are set must be diagnosed first unless you were sent to this diagnostic from a specific DTC diagnostic.
Does the blower motor operate in any speed position? | -- | Go to Step 3 | Go to Blower Motor Inoperative. |
3 | Does the blower motor operate at the desired speeds? | -- | Go to Step 4 | Go to Blower Motor Malfunction. |
4 |
Does the recirculation door move from the recirculation position to the outside air position? | -- | Go to Step 5 | |
5 |
Important: The ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 6 | |
6 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 1 |
7 | Replace the HVAC control module. Refer to Control Module References. Did you complete the replacement? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |