This procedure provides a test of all functions of the heater/defroster unit.
Control Settings | Correct Results | |||||||
---|---|---|---|---|---|---|---|---|
Mode Knob | Temp Control | Blower Motor Switch | Blower Speed | Side Vent Outlet | Center Vent Outlet | Floor Outlet | Defrost Outlet | Side Window Outlet |
Vent | Cold | Off | Off | No Airflow | No Airflow | No Airflow | No Airflow | No Airflow |
Vent | Cold | 4 High | Ambient Airflow | Ambient Airflow | No Airflow | No Airflow | No Airflow | No Airflow |
Vent | Cold to Hot | 4 | High | Minimum Cold to Hot Airflow | No Airflow | Cold to Hot Airflow | Minimum Cold to Hot Airflow | Minimum Cold to Hot Airflow |
Defroster | Cold to Hot | 4 | High | Minimum cold to Hot Airflow | No Airflow | Minimum Cold to Hot Airflow | Cold to Hot Airflow | Minimum Cold to Hot Airflow |
If any of these settings does not produce the correct results, perform the following diagnostic procedure.
Step | Action | Yes | No |
---|---|---|---|
1 | Verify the customers complaint. Are the customers concerns verified? | Go to Step 2 | System OK |
2 |
Is everything connected properly? | Go to Step 4 | Go to Step 3 |
3 | Repair as necessary. Is the repair complete? | System OK | -- |
4 |
Does the door move freely through its entire range of travel so that it can close at both ends of the range? | Go to Step 5 | Go to Step 3 |
5 | Check the travel of the actuator by turning the control knob with the engine running. Is the actuator OK? | Go to Step 6 | Go to Step 7 |
6 |
Does the system perform properly? | System OK | Go to Step 9 |
7 |
Is there a problem with the vacuum hose or the control? | Go to Step 8 | Go to Step 9 |
8 | Repair the vacuum hose or the control as necessary. Is the repair complete? | System OK | Go to Step 9 |
9 | Recheck the system using the "Control Settings/Correct Results" test in this procedure. Is the repair complete? | System OK | Go to Step 10 |
10 | Check for airflow from the defroster or the vent outlets. Is the high airflow from the defroster or the vent outlets? | Go to Step 11 | Go to Step 12 |
11 | Adjust the heater door at the floor and the vent door to get the proper airflow. Is the repair complete? | System OK | -- |
12 | Switch the mode knob to defrost. Is the defroster airflow OK? | Go to Step 13 | Go to Step 14 |
13 |
Is the repair complete? | System OK | -- |
14 | Check the blower speeds for change in airflow. Does the blower speed increase as the control is turned from 1 to 4? | Go to Step 15 | Refer to Blower Motor Inoperative |
15 |
Is the repair complete? | System OK | Go to Step 16 |
16 |
Does the airflow change? | Go to Step 17 | Go to Step 18 |
17 |
Is the repair complete? | System OK | -- |
18 |
Is the repair complete? | System OK | -- |