Removal Procedure
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 6.5L.
- Remove the generator mounting
bolts from the brace.
- Remove the generator brace bolts.
- Remove the brace.
Installation Procedure
- Install the brace.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator mounting bolts and brace bolts to the brace.
Tighten
• | Tighten the auxiliary generator mounting long bolts to 50 N·m
(37 lb ft). |
| Tightening specifications include bolts
for right mounted brace. |
• | Tighten the auxiliary generator mounting short bolts to 25 N·m
(18 lb ft). |