The instrument panel cluster (IPC) diagnostic system check is a test to identify an electronic system malfunction. The IPC diagnostic system check is the starting point for any IPC complaints. Understanding and using the IPC diagnostic system check table will reduce diagnostic time and prevent the unnecessary replacement of parts.
The step number(s) below refer to the same step number(s) in the IPC diagnostic system check table.
This step determines if the scan tool can be powered up by the data link connector
Since most of the diagnostic procedures require a scan tool, serial data must be available. This step determines if communications can be established with the IPC.
This step determines if the Class 2 line is operational and can communicate to other module on the line.
This step determines if CKT 340 is shorted to ground and opens the RADIO fuse.
This step determines if CKT 340 is still shorted to ground or if CKT 340 was an intermittent problem.
This step determines if CKT 1020 is shorted to ground and opens the IGN 0 fuse.
This step determines if CKT 1020 is still shorted to ground or if CKT 1020 was an intermittent problem.
This step determines if CKT 41 is shorted to ground and opens the CRUISE fuse.
This step determines if CKT 41 is still shorted to ground or if it was an intermittent problem.
This step determines if CKT 39 is shorted to ground and opens the IGN 1 fuse.
This step determines if CKT 39 is still shorted to ground or if it was an intermittent problem.
This step determines if the IPC CKT 1020 is open between the IPC and the IGN 0 fuse.
This step determines if the IPC CKT 1020 is shorted to battery between the IPC and the IGN 0 fuse.
This step determines if the IPC CKT 340 is open between the IPC and the RADIO fuse.
This step determines if the IPC ground CKT 451 is open
This step determines if the IPC CKT 41 is open between the IPC and the CRUISE fuse.
This step determines if the IPC CKT 39 is open between the IPC and the IGN 1 fuse.
This step determines if the IPC class 2 CKT 1036/1132 is open between the IPC and the data line connector.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Does the scan tool power up? | -- | |||
With the scan tool, attempt to establish communications with the IPC. Does the scan tool communicate with the IPC? | -- | |||
Attempt to establish communications with other class 2 systems (i.e. vehicle control module, (VCM), powertrain control module (PCM), body control module (BCM). Does the scan tool communicate with other class 2 systems? | -- | Go to Scan Tool Does Not Communicate with Class 2 Data Line in wiring systems. | ||
Inspect the RADIO fuse located in the underhood bussed electrical center (UBEC). Is the RADIO fuse open? | -- | |||
Is the RADIO fuse open. | -- | |||
6 |
Is the repair complete? | -- | -- | |
Check the IGN 0 fuse located in the left bussed electrical center (LBEC). Is the IGN 0 fuse open? | -- | |||
Is the IGN 0 fuse open? | -- | |||
9 |
Is the repair complete? | -- | -- | |
Check the CRUISE fuse located in the left bussed electrical center (LBEC). Is the CRUISE fuse open? | -- | |||
Is the CRUISE fuse open? | -- | |||
12 |
Is the repair complete? | -- | -- | |
Check the IGN 1 fuse located in the left bussed electrical center (LBEC). Is the IGN 1 fuse open? | -- | |||
Is the IGN 1 fuse open? | -- | |||
15 |
Is the repair complete? | -- | -- | |
Does the DMM display battery voltage? | 9-16 volts | |||
Does the DMM display battery voltage? | 9-16 volts | |||
Does the DMM display battery voltage? | 9-16 volts | |||
Back probe (to prevent damage to the terminal) with a DMM J 39200 and measure the voltage between the IPC connector CKT 340 (ORN) cavity A9 to CKT 451 (BLK/WHT) cavity A8. Does the DMM display battery voltage? | 9-16 volts | |||
Backprobe (to prevent damage to the terminal) with a DMM J 39200 and measure the voltage between the CKT BRN (41) wire cavity A4 and ground. Does the DMM display battery voltage? | 9-16 volts | |||
Backprobe (to prevent damage to the terminal) with a DMM J 39200 and measure the voltage between the CKT 39 (PNK) cavity B6 and ground. Does the DMM display battery voltage? | 9-16 volts | |||
With a DMM J 39200 measure the resistance between the CKT 1036/1132 (GRY) cavity A5 of the IPC connector and cavity 2 of the data line connector. Is the resistance within a specified range? | 0-5 ohms | |||
23 | Locate and repair the open CKT 1020 (PNK) between the IPC and the IGN 0 fuse. Is the repair complete? | -- | -- | |
24 | Locate and repair open CKT 340 (ORN) between the IPC and the RADIO fuse (located in the underhood bussed electrical center (UBEC). Is the repair complete? | -- | -- | |
25 | Locate and repair open CKT 451 (BLK/WHT) between the IPC and G103. Is the repair complete? | -- | -- | |
26 | Locate and repair open CKT 1036 (GRY) / CKT 1132 (PPL) between the IPC and the data link connector. Is the repair complete? | -- | -- | |
27 | Locate and repair the short to battery in CKT 1020 (PNK) between the IPC and IGN 0 fuse. Is the repair complete? | -- | -- | |
28 | Locate and repair the open in CKT 39 (PNK) between the IPC and IGN 1 fuse. Is the repair complete? | -- | -- | |
29 | Locate and repair the open in CKT 41 (BRN) between the IPC and CRUISE fuse. Is the repair complete? | -- | -- | |
30 | Replace the IPC Instrument Cluster Replacement Is the repair complete? | -- | -- | |
31 |
Are all DTCs cleared? | -- | -- |