Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important: The Automatic Transmission (A/T) Wiring Harness Assembly Check cannot be used for checking the automatic transmission fluid pressure (TFP) manual valve position switch circuit. Refer to Transmission Fluid Pressure Manual Valve Position Switch Resistance Check for those circuits. | ||||||||||||||
1 |
Is the resistance within the values indicated? | 19-24ohms @ 20°C (68°F) 24-31ohms @ 100°C (212°F) | ||||||||||||
2 |
Is the resistance within the values indicated? | 19-24ohms @ 20°C (68°F) 24-31ohms @ 100°C (212°F) | ||||||||||||
3 | Measure the resistance between terminals B and E (2-3 shift solenoid valve). Is the resistance within the values indicated? | 19-24ohms @ 20°C (68°F) 24-31ohms @ 100°C (212°F) | ||||||||||||
4 |
Is the resistance within the values indicated? | 19-24ohms @ 20°C (68°F) 24-31ohms @ 100°C (212°F) | ||||||||||||
5 | Measure the resistance between terminals S and E (torque converter clutch pulse width modulation solenoid valve). Is the resistance within the values indicated? | 10-11ohms @ 20°C (68°F) 13-15ohms @ 100°C (212°F) | ||||||||||||
6 |
Is the resistance within the values indicated? | 10-11ohms @ 20°C (68°F) 13-15ohms @ 100°C (212°F) | ||||||||||||
7 | Measure the resistance between terminals C and D (pressure control solenoid valve). Is the resistance within the values indicated? | 3-5ohms @ 20°C (68°F) 4-7ohms @ 100°C (212°F) | ||||||||||||
8 |
Is the resistance within the values indicated? | 3-5ohms @ 20°C (68°F) 4-7ohms @ 100°C (212°F) | ||||||||||||
9 | Measure the resistance between terminals L and M (transmission fluid temperature sensor). Is the resistance within the values indicated? | 3333-3689ohms @ 20°C (68°F) 167-189ohms @ 100°C (212°F) | ||||||||||||
10 | Measure the resistance from terminals A, B, C, D, E, L, M, N, P, R and S of the A/T wiring harness assembly at the transmission 20-way connector, to the transmission case. Is the resistance measured greater than the value indicated? | 250kohms | System OK | |||||||||||
11 |
Is the resistance measured greater than the value indicated? | 250kohms | ||||||||||||
12 | Inspect for high resistance or a shorted condition:
Was high resistance or a shorted condition found? | -- | ||||||||||||
13 | Replace the A/T wiring harness assembly. Is the replacement complete? | -- | -- | |||||||||||
14 | Replace the faulty component. Is the replacement complete? | -- | -- |