Step | Action | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the air distribution outlets. | |||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||
2 |
Is the blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On | ||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate at all? | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||
4 | Does the blower motor operate correctly for each speed position? | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||
5 | Is the vehicle equipped with A/C? | Go to Step 6 | Go to Step 7 | ||||||||
6 |
Does the recirculation door move to the recirculation position? | Go to Step 7 | |||||||||
7 | Inspect the mode door cable and linkage the following conditions:
Did you find and correct the condition? | Go to Step 8 | |||||||||
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |