• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Pressure Sensor 5-Volt Reference Voltage | P2432 | P2432 | P2431 | P2430, P2431 |
Pressure Sensor Signal | P2432 | P2432 | P2433 | P2430, P2431 |
Pressure Sensor Low Reference | -- | P2433 | -- | -- |
Pump Voltage Supply | P0411 | P0411 | 2444 | -- |
Pump Ground | -- | P0411 | -- | -- |
Solenoid Voltage Supply | P0411 | P0411 | 2440 | -- |
Solenoid Ground | -- | P0411 | -- | -- |
Pump Relay Coil Voltage Supply | P0411, P0418 | P0411, P0418 | -- | -- |
Pump Relay Coil Control | P0418, P2444 | P0411, P0418 | P0418 | -- |
Pump Relay Switch Supply | P0411 | P0411 | -- | -- |
Solenoid Relay Coil Voltage Supply | P0411, P0412 | P0411, P0412 | -- | -- |
Solenoid Relay Coil Control | P0412, P2440 | P0411, P0412 | P0412 | -- |
Solenoid Relay Switch Supply | P0411 | P0411 | -- | -- |
Circuit | Normal Range | Short to Ground | Open | Short to Voltage |
---|---|---|---|---|
Operating Conditions: Key ON, Engine OFF | ||||
5-Volt Reference Voltage | BARO | 41 kPa | 41 kPa | 111 kPa |
Pressure Sensor Signal | BARO | 42 kPa | 41 kPa | 150 kPa |
Low Reference | BARO | BARO | 145 kPa | BARO |
The secondary air injection (AIR) system aids in the reduction of hydrocarbon emissions during a cold start. The system forces fresh filtered air into the exhaust stream in order to accelerate the catalyst operation. An electric air pump, the secondary AIR injection pump, provides filtered air on demand to the AIR control solenoid valve/pressure sensor assembly. The AIR control solenoid valve/pressure sensor assembly controls the flow of air from the AIR pump to the exhaust manifold. The AIR valve relay supplies the current needed to operate the AIR control solenoid valve/pressure sensor assembly. A pressure sensor is used to monitor the air flow from the AIR pump. The powertrain control module (PCM) supplies the internal pressure sensor with a 5-volt reference, an electrical ground, and a signal circuit.
The AIR diagnostic uses 3 phases to test the AIR system:
During phase 1, both the AIR pump and the solenoid valve are activated. Normal secondary air function occurs. Expected system pressure is 8-10 kPa above barometric pressure (BARO).
During phase 2, only the AIR pump is activated. The solenoid valve is closed. Pressure sensor performance and solenoid valve deactivation are tested. Expected system pressure is 20-25 kPa above BARO.
During phase 3, neither the AIR pump nor the solenoid valve is activated. AIR pump deactivation is tested. Expected system pressure equals BARO.
In all 3 phases, testing is accomplished by comparing the measured pressure against the expected pressure. The PCM can detect faults in the AIR pump, AIR control solenoid valve/pressure sensor assembly, and the exhaust check valve. The pressure sensor can also detect leaks and restrictions in the secondary AIR system plumbing.
• | DTCs P0101, P0102, P0103, P0106, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0125, P0128, P0201, P0202, P0203, P0204, P0300, P0412, P0418, P0420, P0606, P1106, P1107, P1111, P1112, P1114, P1115, P1635, P1639, P2430, P2431, P2432, P2433 are not set. |
• | More than 60 minutes has elapsed since the last cold start. |
• | The system voltage is 9-18 volts. |
• | The BARO parameter is more than 70 kPa. |
• | The MAF sensor parameter is less than 33 g/s. |
• | The AIR system is commanded ON. |
• | The conditions are stable for more than 5 seconds. |
• | DTC P2440 runs once per trip start up when the above conditions are met and AIR pump operation is requested. |
• | The AIR system does not meet expected pressure conditions. |
• | DTC P2440 sets with in 8 seconds when the above conditions are met. |
DTC P2440 is a Type B DTC.
DTC P2440 is a Type B DTC.
• | If any secondary air injection system pressure sensor circuit DTCs are set, perform those diagnostics first. |
• | Inspect the AIR hoses/pipes between the pump and the shut-off valve for leaks. |
• | Engine running, enable the AIR pump and observe that the AIR Pressure Sensor parameter increases to approximately 20-25 kPa above BARO. |
Important: You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
⇒ | If the test lamp is illuminated, test for a short to voltage on the solenoid voltage supply circuit. If the circuit tests normal, test or replace the relay. |
• | Control Module References for PCM replacement and programming |
With the engine running, enable the AIR pump and observe that the AIR Pressure Sensor parameter increases to approximately 20-25 kPa above BARO.