J 39400-A Halogen Leak Detector
Important: Immediately cap or tape the open front evaporator tube and the condenser in order to prevent contamination.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Important: Fully seat the A/C filter to the ferrules in order to ensure that the O-rings seat inside the filter housing.
Tighten
Tighten the flare nuts to 15 N·m (11 lb ft).