The following DTCs are for the ambient air temperature sensor and for the inside air temperature sensor:
• | B0332 and B0333 are for the ambient air temperature sensor |
• | B0337 and B0338 are for the inside air temperature sensor |
The ambient air temperature sensor allows the HVAC control module to monitor the temperature of the air surrounding the front of the vehicle. The inside air temperature sensor allows the HVAC control module to monitor the temperature of the air inside the passenger compartment. The module applies 5 volts to internal input resistors that are connected to the signal circuits of the air temperature sensors. The module provides ground to the air temperature sensors through the low reference circuits. The HVAC control module monitors the voltage drops across the air temperature sensors and uses the inputs for automatic control calculations. The HVAC control module also uses the ambient air temperature input to calculate the value of the ambient air temperature display. When the air temperatures are cold, the resistances of the sensors are high and the voltage signals are high. When the air temperatures are hot, the resistances of the sensors are low and the voltage signals are low.
The ignition is turned ON.
The HVAC control module determines that the voltage applied to the input for the air temperature sensor is less than 0.09 V, for B0332 and B0337, or more than 4.9 V, for B0333 and B0338.
• | The HVAC control module will store the trouble code in memory. |
• | A default value will be used for the sensor data by the HVAC control module to allow the A/C system to operate. |
• | The DTC will become history if the HVAC control module no longer detects a failure. |
• | The history DTC will clear after 100 fault free ignition cycles. |
• | The DTC can be cleared with a scan tool. |
If condition not present, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The numbers below refer to the step numbers on the diagnostic table.
Tests for the proper operation of the circuit in the high voltage range.
Tests for the proper operation of the circuit in the low voltage range. If the fuse in the jumper opens when you perform this test, the signal circuit is shorted to voltage.
Step | Action | Values | Yes | No |
---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views | ||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the scan tool indicate that the appropriate Temp Sensor parameter is within the specified range? | 0.09-4.90 V | Go to Diagnostic Aids | Go to Step 3 |
Does the scan tool indicate that the appropriate Temp Sensor parameter is more than the specified value? | 4.90 V | Go to Step 4 | Go to Step 5 | |
Does the scan tool indicate that the appropriate Temp Sensor parameter is less than the specified value? | 0.09 V | Go to Step 8 | Go to Step 6 | |
5 | Test the signal circuit of the appropriate air temperature sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 9 |
6 | Test the signal circuit of the appropriate air temperature sensor for a short to voltage, a high resistance, or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 7 |
7 | Test the low reference circuit of the appropriate air temperature sensor for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 9 |
8 | Inspect for poor connections at the harness connector of the appropriate air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 10 |
9 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 12 | Go to Step 11 |
10 | Replace the appropriate air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement or Inside Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 12 | -- |
11 |
Important: Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement . Did you complete the replacement? | -- | Go to Step 12 | -- |
12 |
Does the DTC reset? | -- | Go to Step 2 | System OK |