This test resets HVAC control module and checks for current air temperature actuator DTC.
Ambient air temperature must be above 3°C (38°F) in order for this A/C Compressor test to be run.
Step | Action | Values | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The temperature cannot be adjusted, or cooling is insufficient during the A/C operation. | ||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | -- | Go to Step 2 | |||||||||||
Does the scan tool display DTC B0408, B0409, B0419 or B0423? | -- | Go to Step 3 | ||||||||||||
3 | Place the blower motor switch in each speed position. Does the blower motor operate in any speed position? | -- | Go to Step 4 | Go to Blower Motor Inoperative | ||||||||||
4 | Does the blower motor operate in each speed position? | -- | Go to Step 5 | Go to Blower Motor Malfunction | ||||||||||
5 |
Does the recirculation door move from the recirculation position to the ambient air position? | -- | Go to Step 6 | Go to Air Delivery Improper | ||||||||||
6 | Place the passenger temperature in the OFF position. Does the Too Hot in Vehicle concern occur when A/C cooling desired? | -- | Go to Step 7 | Go to Step 9 | ||||||||||
Important:: Ambient air temperature must be above 3°C (38°F).
Does the A/C compressor operate? | -- | Go to Step 8 | ||||||||||||
8 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 9 | ||||||||||
9 | Inspect the upper left, upper right, lower left, and lower right air temperature sensors for the following conditions:
Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 10 | ||||||||||
10 |
Does the paper stay in place? | -- | Go to Step 11 | Go to Step 14 | ||||||||||
11 |
Does the scan tool indicate that the sensor temperatures are within the specifications at the thermometer temperatures? | -3 to +3°C (-5 to +5°F) | Go to Step 12 | Go to Step 17 | ||||||||||
12 |
Does the scan tool indicate that the Solar Sensor parameter is greater than the specified value? | 224 Counts | Go to Step 13 | Go to Step 19 | ||||||||||
13 |
Do the counts change? | -- | System OK | Go to Step 19 | ||||||||||
14 |
Does the test lamp illuminate? | -- | Go to Step 18 | Go to Step 15 | ||||||||||
15 | Test the ignition 3 voltage circuit of the inside air temperature assembly for a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 16 | ||||||||||
16 | Test the inside air temperature assembly control circuit of the inside air temperature assembly for a short to voltage, a high resistance or an open. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 20 | ||||||||||
17 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table? | -- | Go to Step 20 | Go to Step 18 | ||||||||||
18 | Inspect for poor connections at the harness connector of the suspect air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 21 | ||||||||||
19 | Inspect for poor connections at the harness connector of the sunload sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 22 | ||||||||||
20 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | -- | Go to Step 24 | Go to Step 23 | ||||||||||
21 | Replace the appropriate temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||
22 | Replace the sunload sensor. Refer to Sun Load Sensor Replacement . Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||
23 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | -- | Go to Step 24 | -- | ||||||||||
24 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |