Removal Procedure
- Remove the instrument panel (I/P) upper trim panel. Refer to
Instrument Panel Upper Trim Panel Replacement
in
Instrument Panel, Gages, and Console.
- Remove the defroster air outlet screws from the I/P upper trim panel.
- Remove the defroster air outlet from the I/P upper trim panel.
Installation Procedure
- Inspect the seals, and replace if damaged, using Kent Industries adhesive
backed foam tape P/N 46485 or equivalent.
- Install the defroster air outlet to the I/P upper trim panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the defroster air outlet screws to the I/P upper trim panel.
Tighten
Tighten the screws to 1 N·m (9 lb in).
- Install the instrument panel upper trim panel. Refer to
Instrument Panel Upper Trim Panel Replacement
in Instrument Panel,
Gages, and Console.