GM Service Manual Online
For 1990-2009 cars only

Step

Action

Value(s)

Yes

No

Schematic Reference: Instrument Cluster Schematics

Connector End View Reference: Master Electrical Component List in Wiring Systems

DEFINITION: This diagnostic procedure applies only to the serial data gages located in the instrument cluster which include the engine coolant temperature gage, and the volt gage.

1

Did you perform the Instrument Cluster Diagnostic System Check?

--

Go to Step 2

Go to Diagnostic System Check - Instrument Cluster

2

  1. Turn the ignition ON, with the engine OFF.
  2. Install a scan tool.
  3. With the scan tool, perform the Displays Test.

Does the gage move from 0 to its maximum value and back to 0 when you perform the Displays Test?

--

Go to Step 3

Go to Step 4

3

  1. Install a scan tool.
  2. Start the engine.
  3. Observe the appropriate parameter in the PCM Data list. Refer to Scan Tool Data List .

Does the parameter match the gage display?

--

Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems

Go to Step 4

4

Important: Program the replacement IPC.

Replace the IPC. Refer to Instrument Cluster Replacement .

Did you complete the replacement?

--

Go to Step 5

--

5

  1. Use the scan tool in order to clear any induced DTCs.
  2. Operate the system in order to verify the repair.

Did you correct the condition?

--

System OK

Go to Step 2