Removal Procedure
- Remove the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in Instrument Panel,
Gauges and Console.
- Disconnect the vacuum
lines (1) from the defroster vacuum actuator.
- Released the defroster vacuum actuator retaining clip (2) from
the HVAC module.
- Rotate the air inlet vacuum actuator in order to disconnect the
actuator shaft (3).
- Remove the air inlet vacuum actuator from the module.
Installation Procedure
- Rotate the defroster vacuum
actuator in order to connect the actuator shaft (3).
- To install, align the actuator and press inward to engaged on
the mounting tabs on the HVAC module (2).
- Connect the vacuum lines (1) to the defroster vacuum actuator.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
in
Instrument Panel, Gauges and Console.
- Install the right side instrument panel insulator. Refer to
Instrument Panel Insulator Replacement
in
Instrument Panel, Gauges and Console.