Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the System Diagnostic Check? | -- | Go to Step 2 | Go to Diagnostic System Check |
2 | Inspect Fuse 4 in the fuse block. Is Fuse 4 open? | -- | Go to Step 3 | Go to Step 4 |
3 | Repair the short to ground in CKT 41 (BRN). Is the repair complete? | -- | Go to Step 15 | -- |
4 |
Did the test lamp light? | -- | Go to Step 6 | Go to Step 5 |
5 | Locate and repair a poor connection or an open in CKT 41 (BRN). Is the repair complete? | -- | Go to Step 15 | -- |
6 |
Did the test lamp light? | -- | Go to Step 12 | Go to Step 7 |
7 |
Did the test lamp light? | -- | Go to Step 9 | Go to Step 8 |
8 | Replace the heater -A/C control module. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 15 | -- |
9 | Inspect circuit 65 (PPL) for a poor connection or an open. Is there a poor connection or an open in the circuit? | -- | Go to Step 10 | Go to Step 11 |
10 | Repair the fault in CKT 65 (PPL). Is the repair complete? | -- | Go to Step 15 | -- |
11 | Replace the blower motor relay. Is the repair complete? | -- | Go to Step 15 | -- |
12 | Keep the ignition switch in the RUN position and use a test lamp to backprobe between the blower motor connector terminal A and terminal B. Did the test lamp light? | -- | Go to Step 13 | Go to Step 14 |
13 | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | Go to Step 15 | -- |
14 | Locate and repair a poor or open connection in CKT 150 (BLK) between the blower motor connector terminal A and G205. Is the repair complete? | -- | Go to Step 15 | -- |
15 | Verify that the system operates properly. Does the system operate properly? | -- | System OK | Go to Step 2 |