Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the generator bolts to 22 N·m
(16 lb ft).
Tighten
Tighten the generator terminal nut to 20 N·m
(15 lb ft).
The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply. Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the tensioner. Refer to Engine Mechanical for tensioner information.
Important: Service the generator as a complete unit.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
• | Tighten the bolts to 50 N·m (37 lb ft). |
• | Tighten the nuts to 30 N·m (22 lb ft). |