Important: The support fixture bar must be installed to provide enough access to remove and properly tighten the oil pan bolts.
13.1. | Disconnect the engine wiring harness electrical connector (1) from the generator control module coolant pump (2). |
13.2. | Remove the generator control module coolant pump bolt (3). |
13.3. | Remove the generator control module coolant pump from the oil pan. |
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 75 N·m (55 lb ft).
Tighten
Tighten the bolts to 25 N·m (18 lb ft).
7.1. | Install the generator control module coolant pump to the oil pan. Ensure that the anti-rotation tab is inserted into the hole in the oil pan. |
7.2. | Install the generator control module coolant pump bolt (3). |
Tighten
Tighten the bolt to 25 N·m (18 lb ft).