• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the internal torque value and compares it to the motor generator unit (MGU) delivered torque value. If the delivered torque is not within tolerance, the DTC will set.
The engine is running.
Torque error is greater than 10 N·m for 1 second.
Delivered torque (CAN data) = command torque.
Normal range for 1 second
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If within the specified range, replace the SGCM. |
⇒ | If greater than the specified range, test the circuit for open/high resistance. |
⇒ | If greater than the specified range, test the circuit for open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SGCM replacement, setup, and programming |