- Install the air temperature door.
- Install the lower HVAC module case.
Notice: Refer to Fastener Notice in the Preface section.
- Install the lower HVAC module case screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the mode valve assembly.
- Install the mode valve assembly screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the mode actuator.
- Install the mode actuator screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the air temperature actuator.
- Install the air temperature actuator screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the air inlet assembly.
- Install the air inlet assembly screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the upper center floor air outlet duct.
- Install the upper center floor air outlet duct screws.
Tighten
Tighten the screws to 1.5 N·m (13 lb in).
- Install the lower center floor air outlet duct.
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement
.