Step
| Action
| Yes
| No
|
1
| Did you perform the function test?
| Go to
Step 2
| Go to
Function Test
|
2
|
- Inspect the control cables from the heater control unit to the heater
case.
- Inspect for any improper routing, kinks, and interference.
Do any of the control cables have improper routing, kinks, or interference?
| Go to
Step 6
| Go to
Step 3
|
3
|
- Disconnect the control cable from the door that causes the binding.
- Cycle the door manually.
Does the door bind?
| Go to
Step 5
| Go to
Step 4
|
4
|
- Inspect the heater control unit for binding.
- Remove the heater control unit. Refer to
Control Assembly Replacement
.
- Disconnect the control cable from the heater control unit in order to
determine if the cable or the control unit is binding.
Does control binding exist?
| Go to
Step 7
| Go to
Step 8
|
5
|
- Remove the heater case. Refer to HVAC Module Assembly
Replacement
.
- Inspect for the following conditions:
- Replace the door seal or replace the heater case.
Is the repair complete?
| Go to
Function Test
| --
|
6
|
- Route the control cables in order to avoid interference with the instrument
panel components.
- Replace any control cables that are kinked. Refer to the following:
Is the repair complete?
| Go to
Function Test
| --
|
7
| Replace the heater control unit. Refer to
Control Assembly Replacement
.
Is the repair complete?
| Go to
Function Test
| --
|
8
| Replace the corresponding control cable. Refer to the following:
Is the repair complete?
| Go to
Function Test
| --
|