Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the HVAC System Check? | Go to Step 2 | Go to HVAC System Check |
2 | Test for an open in the BLK/WHT wire between the blower motor and the blower motor resistor. Is an open present? | Go to Step 6 | Go to Step 3 |
3 |
Is an open present in any of the above tests? | Go to Step 4 | Go to Step 5 |
4 | Replace the blower speed selector switch. Refer to Blower Switch Replacement . Is the repair complete? | Go to HVAC System Check | -- |
5 | Replace the blower motor resistor. Refer to Blower Motor Resistor Replacement . Is the repair complete? | Go to HVAC System Check | -- |
6 | Repair the open in the BLK/WHT wire between the blower motor resistor and S200. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to HVAC System Check | -- |