Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Door Lock/Indicator Schematics | |||
1 | Did you perform the Power Door System Diagnostic System Check? | Go to Step 2 | |
2 | Actuate the door lock switch to both the lock and unlock positions. Did both the doors lock and unlock from the switch? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Did the door lock switch lock and unlock the driver door? | Go to Step 4 | |
4 |
Did the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 |
Did the test lamp illuminate? | Go to Step 8 | Go to Step 7 |
6 | Repair the open in the door lock motor lock circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 10 | -- |
7 | Repair the open in the door lock motor unlock circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 10 | -- |
8 | Inspect for poor connections at the door lock actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 10 | Go to Step 9 |
9 | Replace the door lock actuator. Refer to Door Latch Replacement . Did you complete the repair? | Go to Step 10 | -- |
10 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |