The roof door module (RDM) has 2 separate 12-volt reference voltage circuits. They supply a reference voltage to various roof position sensors on one circuit and the power window motors with the other.
This diagnostic procedure supports the following DTC:
DTC B1517 Battery {single or 1} Voltage
• | Battery voltage between 9-16 volts |
• | The roof and windows may be active or inactive |
The DTC will set when the RDM senses a short to ground on either 12-volt reference voltage circuit.
The RDM cannot properly control the power roof or the power windows.
• | When the fault is no longer present, the RDM will change the current DTC to a history DTC. |
• | The RDM will clear the history DTC after 50 fault free ignition cycles. |
• | A current or history DTC can also be cleared using a scan tool. |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Power Window Schematics Connector End View Reference: Power Roof Systems Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | Go to Diagnostic System Check - Vehicle in Vehicle DTC Information |
2 |
Is DTC B1517 set in the RDM as current? | Go to Step 3 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
3 |
Is DTC B1517 still set as current? | Go to Step 4 | Go to Step 5 |
4 |
Is DTC B1517 still set as current? | Go to Step 8 | Go to Step 6 |
5 | Test for a short to ground in the roof position sensor 12-volt reference supply circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 7 |
6 | Inspect for poor connections at the harness connector of the appropriate power window motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 9 |
7 | Inspect for poor connections at the harness connector of the RDM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 11 | Go to Step 10 |
8 | Repair the short to ground in the power window motor 12-volt reference supply circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 11 | -- |
9 |
Important: Perform the window reinitialization procedure. Refer to Power Window Reinitialization in Doors. Replace the appropriate power window motor. Refer to Door Window Regulator Replacement in Doors. Did you complete the replacement? | Go to Step 11 | -- |
10 | Replace the RDM. Refer to Control Module References in Computer/Integrating Systems for replacement, setup, and programming. Did you complete the replacement? | Go to Step 11 | -- |
11 |
Does the DTC reset? | Go to Step 2 | System OK |