Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics Connector End View Reference: Instrument Panel, Gages, and Console Connector End Views and Power Roof Systems Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
2 |
Does the temperature displayed on the temperature gage match the current room temperature? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Important: Verify the J 33431-C Signal Generator and Instrument Panel Tester resistance settings with a DMM. Does the Ambient Air Temp. Sensor parameter change value with change in resistance? | Go to Step 4 | Go to Step 5 |
4 | Does the value of the temperature gage match the value of the Ambient Temp. Sensor parameter with change in resistance? | Go to Step 8 | Go to Step 9 |
5 | Test the ambient air temperature sensor signal circuit for a high resistance, a short to voltage, or a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 6 |
6 | Test the ground circuit of the ambient air temperature sensor for a high resistance or a short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 7 |
7 | Inspect for poor connections at the harness connector of roof and door module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 10 |
8 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the auxiliary gage package. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Replace the roof and door module. Refer to Folding Top Control Module Replacement . Did you complete the replacement? | Go to Step 13 | -- |
11 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement . Did you complete the replacement? | Go to Step 13 | -- |
12 | Replace the auxiliary gage package. Refer to Outside Air Temperature and Voltmeter and Torque Meter Gauge Package Replacement . Did you complete the replacement? | Go to Step 13 | -- |
13 |
Did you correct the condition? | System OK | Go to Step 2 |