Symptom | Correction | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Low Side Pressure | High Side Pressure | ||||||||||||||
150-300 kPa (21-43 psi) | 1275-1670 kPa (185-244 psi) | Normal | |||||||||||||
Vacuum | 500-600 kPa (71-85 psi) |
Replace the expansion valve and the receiver dryer, and evacuate and recharge the system. Refer to the following: | |||||||||||||
Normal to vacuum | Normal to 690-980 kPa (100-142 psi) | The expansion valve is frozen due to moisture in the system, temporarily shutting down the refrigeration cycle. Replace the expansion valve and the receiver dryer, and evacuate and recharge the system. Refer to the following: | |||||||||||||
50-100 kPa (4-14 psi) | 690-980 kPa (100-142 psi) | Insufficient refrigerant in system. Leak test the system, repair and recharge. Refer to Leak Testing and Refrigerant Recovery and Recharging . | |||||||||||||
400-600 kPa (57-85 psi) | 690-980 kPa (100-142 psi) | Internal leak in compressor. Replace the compressor. Refer to Air Conditioning Compressor Replacement . | |||||||||||||
250-300 kPa (36-43 psi) | 1960-2450 kPa (285-355 psi) |
| |||||||||||||
300-400 kPa (43-57 psi) | 1960-2450 kPa (285-355 psi) |
| |||||||||||||
Normal to low | Low | Low side restriction. Inspect for a kinked tube/hose, or a clogged suction screen. | |||||||||||||
Normal to low | Normal to high | High side restriction. Visually inspect for frost spot. Feel along tubing for temperature change. | |||||||||||||
Center Outlet Air Temperature Above Specifications |
| ||||||||||||||
Center Outlet Air Temperature Below Specifications |
|
Step | Action | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important: Some conditions which are normal to correct air conditioning (A/C) system is operation may lead an owner to wrongly suspect a problem exists. Under conditions of high humidity, the air discharged from the A/C system may not feel as cold as expected. This is because the vaporized moisture in humid air heats more effectively than does dry air, making the humid air much harder to cool. In terms of overall comfort, however, the dryer, dehumidified air coming from the A/C system during hot, humid weather, evaporates more moisture on a person's skin and provides more of a cooling effect than air which is cooler but more humid. This fact should be explained to an owner if a mechanical cause for a persistent complaint of insufficient cooling cannot be found. Refer to Symptoms - HVAC Systems - Manual . | |||||||||||||
1 |
Did you find and correct the condition? | Go to Step 18 | Go to Step 2 | ||||||||||
2 |
Did you find and correct the condition? | Go to Step 18 | Go to Step 3 | ||||||||||
3 | Inspect the blower motor for proper operation. The blower motor speed should increase at each speed level as the switch is turned towards HIGH and then decrease as the switch is turned towards LOW. Did you find and correct the condition? | Go to Step 18 | Go to Step 4 | ||||||||||
4 | Inspect for a loose, damaged, slipping or missing compressor drive belt. Refer to Generator and Air Conditioning Compressor and Power Steering Pump Belt Replacement 2.0 L or Drive Belt Replacement - Air Conditioning Compressor and Power Steering 2.5 L in Engine Mechanical. Did you find and correct the condition? | Go to Step 18 | Go to Step 5 | ||||||||||
5 | Inspect the condenser fan for correct operation. Refer to Condenser Fan Inoperative . Did you find and correct the condition? | Go to Step 18 | Go to Step 6 | ||||||||||
6 |
Did you find and correct the condition? | Go to Step 18 | Go to Step 7 | ||||||||||
7 |
Does the compressor clutch plate turn freely by hand? | Go to Step 8 | |||||||||||
8 |
Are the High and the Low side pressures 345 kPa (50 psi) or higher? | Go to Step 9 | Go to Step 13 | ||||||||||
9 |
Does the compressor clutch engage? | Go to Step 10 | |||||||||||
10 |
Is there excessive compressor noise? | Go to Step 11 | |||||||||||
11 |
Did you find and correct the condition? | Go to Step 18 | Go to Step 12 | ||||||||||
12 | Feel the evaporator inlet pipe (the small pipe) and the evaporator outlet pipe at the bulkhead. The evaporator inlet pipe should feel warm to the touch. The evaporator outlet pipe should feel cool to the touch. Does the evaporator inlet pipe feel colder than the evaporator outlet pipe? | Go to Step 13 | Go to Step 15 | ||||||||||
13 |
Is a leak present? | Go to Step 14 | Go to Step 16 | ||||||||||
14 | Repair the leak. Refer to Leak Testing and Refrigerant Recovery and Recharging . Is the repair complete? | Go to Step 18 | -- | ||||||||||
15 |
High Side Pressure Range Low Side Pressure Range Does the compressor stay engaged outside the specified values? | Go to Step 17 | Go to Step 16 | ||||||||||
16 |
Is the repair complete? | Go to Step 18 | -- | ||||||||||
17 | Replace the A/C refrigerant pressure switch. Refer to Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement . Is the repair complete? | Go to Step 18 | -- | ||||||||||
18 | Operate the system in order to verify the repair. Refer to Air Conditioning (A/C) System Performance Test . Did you correct the condition? | System OK | Go to Step 1 |