Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics | |||
1 | Did you review the Air Delivery Description and Operation and the Air Temperature Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Operate the blower motor at each speed. Does the blower motor operate at any speed? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 12 | Go to Step 4 |
4 |
Is battery voltage present? | Go to Step 9 | Go to Step 5 |
5 | Test the blower motor supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 6 |
6 | Test the blower relay switch supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 7 |
7 | Test the blower relay coil supply voltage circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 8 |
8 | Test the blower relay coil ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 13 |
9 | Test the blower motor ground circuit for an open between the blower motor and S204. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 10 |
10 | Test the blower switch ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 11 |
11 | Test the blower switch for a high resistance or for an open in each speed position. Refer to Circuit Testing in Wiring Systems and Blower Switch Replacement . Did you find and correct the condition? | Go to Step 16 | -- |
12 | Inspect for a poor connection at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 14 |
13 | Inspect for a poor connection at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 16 | Go to Step 15 |
14 | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement? | Go to Step 16 | -- |
15 | Replace the blower motor relay. Refer to Blower Motor Relay Replacement . Did you complete the replacement? | Go to Step 16 | -- |
16 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |