Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics | |||
1 | Did you review the Interior Lights Circuit Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the dome lamps are always on. Does the system operate normally | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Refer to Circuit Testing in Wiring Systems. Is a short to ground present? | Go to Step 4 | Go to Step 5 |
4 | Repair the short to ground in the door jamb switch circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 8 | -- |
5 | Test the ground circuit of the Dome lamp circuit for a short to ground. Refer to Wiring Repairs in Wiring Systems. Is a short to ground present? | Go to Step 6 | Go to Step 7 |
6 | Repair the short to ground in the dome lamp ground circuit. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 8 | -- |
7 | Replace the Remote Control Door Lock Receiver. Refer to Remote Control Door Lock Receiver Replacement in Keyless Entry. Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |