Removal Procedure
- Remove the midgate inner panel. Refer to
Midgate Inner Panel Replacement
.
- Disconnect the electrical connector from the window position switch.
- Remove the window position switch from the window regulator bracket by
sliding it off the window regulator bracket.
Installation Procedure
- Install the window position switch to the
window regulator bracket by sliding it on the bracket until the retaining feature
is fully engaged.
- Connect the electrical connector to the window position switch.
- Install the midgate inner panel. Refer to
Midgate Inner Panel Replacement
.