The most likely causes of insufficient heating outside the heater system include a low coolant level, a faulty thermostat, a partially or fully clogged heater core or hose, an obstruction to the air circulation, or an air leak past a faulty seal into the passenger compartment. For the proper temperature verification, use the Tech II.
Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Inspect for the following conditions:
Does the malfunction still exist? | -- | Go to Step 2 | System OK | ||||||||||||
2 |
Is the airflow high? | -- | Go to Step 3 | Go to Step 6 | ||||||||||||
3 | Does the airflow change with different blower speeds? | -- | Go to Step 4 | Go to Step 10 | ||||||||||||
4 | Perform the heater output temperature check. Refer to Heater Output Temperature Check in Heater and Ventilation (Non-A/C). Is the heater output temperature correct? | -- | Go to Step 5 | Go to Step 11 | ||||||||||||
5 |
Is the repair complete? | -- | System OK | -- | ||||||||||||
6 | Perform the function test. Refer to Function Test . Is the repair complete? | -- | System OK | Go to Step 7 | ||||||||||||
7 | Check the airflow from the vent outlets. Is the airflow from the vent outlets high? | -- | Go to Step 8 | Go to Step 16 | ||||||||||||
8 | Move the defroster and/or the vent valve to the HEATER mode. Is the defroster airflow correct? | -- | Go to Step 9 | Go to Step 17 | ||||||||||||
9 |
Does the airflow change with different blower speeds? | Go to Step 8 | Go to Step 10 | |||||||||||||
10 |
Is the heater output temperature correct? | -- | Go to Step 5 | Go to Step 11 | ||||||||||||
11 |
Is the temperature valve fully closed? | -- | Go to Step 12 | Go to Step 21 | ||||||||||||
12 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 13 | Go to Step 22 | ||||||||||||
13 |
Were the hoses properly installed? | -- | Go to Step 14 | Go to Step 24 | ||||||||||||
14 |
Is the air temperature around both hoses at least at the specified value? | 24°C (85°F) | Go to Step 15 | Go to Step 22 | ||||||||||||
15 | Replace the heater core. Refer to Heater Core Replacement in Heater and Ventilation (Non-A/C). Is the repair complete? | -- | System OK | -- | ||||||||||||
16 |
Is the defroster airflow not present or low? | -- | Go to Step 17 | Go to Step 9 | ||||||||||||
17 | Does the airflow change with different blower speeds? | -- | Go to Step 18 | Go to Step 10 | ||||||||||||
18 | Inspect for airflow obstructions at the blower inlet and plenum. Did you find and correct a condition? | -- | System OK | Go to Step 19 | ||||||||||||
19 |
Is a change in the airflow audible? | -- | Go to Step 20 | Go to Step 25 | ||||||||||||
20 | Check for an airflow obstruction between the blower and the system outlets. Is the repair complete? | -- | System OK | -- | ||||||||||||
21 |
Did you find and correct a condition? | -- | System OK | -- | ||||||||||||
22 | Check the thermostat for proper installation and sealing. Is the thermostat properly installed and seated? | -- | Go to Step 26 | Go to Step 23 | ||||||||||||
23 | Reinstall the thermostat. Is the repair complete? | -- | Go to Step 12 | -- | ||||||||||||
24 | Properly reinstall the hoses. Is the repair complete? | -- | Go to Step 12 | -- | ||||||||||||
25 | Inspect the following components:
Is the repair complete? | -- | System OK | -- | ||||||||||||
26 | Replace the thermostat. Is the repair complete? | -- | System OK | -- |