Important: Do not evacuate the air conditioning system.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the power steering pump mounting bracket bolts and nut to 41 N·m
(30 lb ft).
Tighten
Tighten the power steering pump mounting bracket to power steering pump
bolts to 50 N·m (37 lb ft).
Tighten
Tighten the junction block bracket bolt to 25 N·m (18 lb ft).
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the generator mounting bracket bolts and nut to 41 N·m
(30 lb ft).
Tighten
Tighten the heater hose bracket bolt to 25 N·m (18 lb ft).
Tighten
Tighten the wiring harness bracket bolt to 25 N·m (18 lb ft).