Step
| Action
| Value(s)
| Yes
| No
|
1
| Has the Power Door Locks System
Check been performed?
| --
| Go to
Step 2
| Go to
Power Door Locks System Check
|
2
|
- Disconnect the inoperative power door lock switch.
- Connect a J 35616-200
test lamp from CKT 640 (ORN) to the power door lock switch and
ground.
Does the test lamp light?
| --
| Go to
Step 3
| Go to
Step 4
|
3
|
- Connect a fused jumper from the inoperative power door lock switch,
CKT 640 (ORN) to CKT 194 (LT BLU).
- Connect the fused jumper from the inoperative power door lock
switch, CKT 640 (ORN) TO CKT 194 (WHT).
Do the doors lock and then unlock?
| --
| Go to
Step 5
| Go to
Step 6
|
4
| Repair the open in CKT 640
(ORN) between the inoperative power door lock switch and splice S256. Refer
to
Wiring Repairs
in Wiring
Systems.
Is the repair complete?
| --
| Go to
Power Door Locks System Check
| --
|
5
| Replace the door lock switch. Refer to
Power Accessory Switch Panel Replacement
.
Is the repair complete?
| --
| Go to
Power Door Locks System Check
| --
|
6
|
- Inspect CKT 194 (WHT) and CKT 195 (LT BLU) for opens.
- Repair the circuits, as necessary. Refer to
Wiring Repairs
in Wiring Systems.
Is the repair complete?
| --
| Go to
Power Door Locks System Check
| --
|