Do not tighten the bolt.
Notice: Use the correct fastener in the correct location. Replacement fasteners must be the correct part number for that application. Fasteners requiring replacement or fasteners requiring the use of thread locking compound or sealant are identified in the service procedure. Do not use paints, lubricants, or corrosion inhibitors on fasteners or fastener joint surfaces unless specified. These coatings affect fastener torque and joint clamping force and may damage the fastener. Use the correct tightening sequence and specifications when installing fasteners in order to avoid damage to parts and systems.
3.1. | Slide the regulator rollers into the glass channel. |
3.2. | Align the inner panel lower front corner bolt with the hole in the front glass channel assembly. |
3.3. | Tighten the front channel top bolt. |
Tighten
Tighten the bolt to 2 N·m (18 lb in).
3.4. | Tighten all of the inner panel bolts. |
Tighten
Tighten the bolts to 2 N·m (18 lb in).