Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The Charge Indicator (battery) lamp never lights. | ||||
1 | Did you review the Charging System description and operation and perform the necessary inspections? | -- | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is the Charge indicator lamp lit? | -- | Go to Step 4 | Go to Step 5 |
4 |
Is the repair complete? | -- | Go to Step 12 | -- |
5 |
Is continuity present? | -- | Go to Step 6 | Go to Step 7 |
6 | Check for an open filament in the Charge Indicator lamp. Is the filament open? | -- | Go to Step 8 | Go to Step 9 |
7 | Locate and repair the open in CKT 25 (BRN) between the instrument panel and the generator(s). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
8 | Replace Charge Indicator lamp. Refer to Instrument Cluster Bulb Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
9 |
Is B+ present at the instrument cluster? | -- | Go to Step 10 | Go to Step 11 |
10 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
11 | Locate and repair the open in CKT 39 (PNK) between the IP fuse block and the instrument cluster. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |