Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: Charge Indicator (battery) lamp stays on when engine is running. | ||||
1 | Did you review the Charging System description and operation and perform the necessary inspections? | -- | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the Charge Indicator remain lit with the generator(s) unplugged and the ignition turned ON? | -- | Go to Step 9 | Go to Step 4 |
4 |
Is volt drop more than the specified amount? | 0.3 volt | Go to Step 6 | Go to Step 5 |
5 |
Is volt drop more than the specified amount? | 0.2 volt | Go to Step 7 | Go to Step 8 |
6 | Locate and repair the open or high resistance in CKT 2 (RED) between the generator and battery positive terminal. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
7 | Locate and repair the open or high resistance between the generator case and battery negative terminal. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
8 | Replace the generator(s). Refer to Generator Replacement or Auxiliary Generator Replacement . Does the battery indicator remain lit? | -- | Go to Step 6 | Go to Step 8 |
9 |
Is continuity present? | -- | Go to Step 6 | Go to Step 7 |
10 | Locate and repair the short to ground in CKT 25 (BRN) between the instrument cluster and the generator(s). Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 12 | -- |
11 | Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Cluster And Gages, in Electrical Diagnosis. Is the repair complete? | -- | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |