Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: The front blower motor operates in HI speed only. | ||||
1 | Did you review the HVAC blower operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms in HVAC Systems-Manual |
2 |
Does the blower motor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | -- | Go to Step 6 | Go to Step 4 |
4 |
Is continuity present? | -- | Go to Step 5 | Go to Step 7 |
5 | Repair the open in CKT 72 (LT BLU). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 8 | -- |
6 | Replace the blower motor resistor/relay. Refer to Blower Motor Resistor Replacement . Did you complete the repair? | -- | Go to Step 8 | -- |
7 | Replace the heater and A/C controller. Refer to Control Assembly Replacement . Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the blower motor in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |