Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
DEFINITION:
| ||||||||
1 | Did you review the HVAC blower operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms in HVAC Systems-Manual | ||||
2 |
Does the blower motor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||
3 |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 9 | ||||
4 | Connect a J 35616-200 unpowered test lamp between auxiliary blower motor low speed relay connector cavity C2 for CKT 341 (BRN) and ground. Refer to Circuit Testing in Wiring Systems. Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 10 | ||||
5 |
Is continuity present? | -- | Go to Step 6 | Go to Step 11 | ||||
6 |
Is continuity present? | -- | Go to Step 7 | Go to Step 14 | ||||
7 |
Is continuity present? | -- | Go to Step 8 | Go to Step 12 | ||||
8 |
Is continuity present? | -- | Go to Step 15 | Go to Step 13 | ||||
9 | Repair the open in CKT 1542 (RED) between the underhood fuse-relay center and splice S412. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||
10 | Repair the open in CKT 341 (BRN) between the instrument panel fuse block and splice S405. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||
11 | Repair the open in CKT 150 (BLK) between the front auxiliary HVAC control module and ground G400. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||
12 | Repair the open in CKT 150 (BLK) between the auxiliary blower motor and ground G400. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||
13 | Repair the open in CKT 1172 (YEL) between splice S413 and the auxiliary blower motor. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | Go to Step 16 | -- | ||||
14 | Replace the front auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front . Did you complete the repair? | -- | Go to Step 16 | -- | ||||
15 | Replace the auxiliary blower motor. Refer to Auxiliary Blower Motor Replacement . Did you complete the repair? | -- | Go to Step 16 | -- | ||||
16 | Operate the auxiliary blower motor in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |
Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
DEFINITION:
| ||||||||
1 | Did you review the HVAC blower motor operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms | ||||
2 |
Does the blower motor operate? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 | ||||
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 14 | ||||
4 |
Does the test lamp light? | -- | Go to Step 5 | Go to Step 15 | ||||
5 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 16 | ||||
6 | Does the auxiliary blower motor operate when controlled by the rear auxiliary HVAC control module? | -- | Go to Step 7 | Go to Step 10 | ||||
7 |
Is continuity present? | -- | Go to Step 8 | Go to Step 17 | ||||
8 |
Is continuity present? | -- | Go to Step 9 | Go to Step 18 | ||||
9 |
Is continuity present? | -- | Go to Step 19 | Go to Step 20 | ||||
10 |
Is continuity present? | -- | Go to Step 11 | Go to Step 17 | ||||
11 |
Is continuity present? | -- | Go to Step 12 | Go to Step 21 | ||||
12 |
Did the diode test good? | -- | Go to Step 13 | Go to Step 22 | ||||
13 |
Is continuity present? | -- | Go to Step 23 | Go to Step 24 | ||||
14 | Repair the open in CKT 1542 (RED) between the underhood fuse-relay center and splice S412. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
15 | Repair the open in CKT 341 (BRN) between the instrument panel fuse block and splice S405. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
16 | Repair the open in CKT 150 (BLK) between the front auxiliary HVAC control module connector and ground G400. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
17 | Replace the front auxiliary HVAC control module. Refer to Auxiliary Air Conditioning (A/C) Control Assembly Replacement - Front . Is the repair complete? | -- | Go to Step 25 | -- | ||||
18 | Repair the open in CKT 150 (BLK) between the auxiliary blower motor connector and ground G400. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
19 | Replace the auxiliary blower motor. Refer to Control Assembly Replacement - Auxiliary . Is the repair complete? | -- | Go to Step 25 | -- | ||||
20 | Repair the open in CKT 1172 (YEL) between splice S413 and the auxiliary blower motor. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
21 | Repair the open in CKT 203 (LT BLU) between the front auxiliary HVAC control module and the heater and A/C control logic module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
22 | Replace the heater and A/C control logic module. Refer to Control Assembly Replacement - Auxiliary in Overhead Console . Is the repair complete? | -- | Go to Step 25 | -- | ||||
23 | Repair the open in CKT 77 (DK BLU between the heater and A/C control logic module connector and the rear auxiliary HVAC control module connector. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 25 | -- | ||||
24 | Replace the rear auxiliary HVAC control module. Refer to Control Assembly Replacement - Auxiliary in Overhead Console . Is the repair complete? | -- | Go to Step 25 | -- | ||||
25 | Operate the auxiliary blower motor in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |