Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you review the Remote Keyless Entry System description and operation and perform the necessary inspections? | -- | Go to Step 2 | Go to Symptoms |
2 | Verify the fault is present. Does the system operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is the test lamp lit? | -- | Go to Step 4 | Go to Step 5 |
4 | Repair short to B+ in the WHT (194) wire. Refer to Testing for a Short to Voltage and Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | -- |
5 |
Did the test lamp light? | -- | Go to Step 6 | Go to Step 7 |
6 | Replace the power door lock control module. Is the repair complete? | -- | Go to Step 8 | -- |
7 | Repair the open in CKT 194 (WHT) between splice S242 and the power door lock control module. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |