The number(s) below refer to the step number(s) on the diagnostic table.
The auxiliary blower motor switch control circuit is the circuit that enables the rear auxiliary HVAC control assembly when the front auxiliary blower motor switch is placed in the rear control position.
The auxiliary blower motor switch control circuit is the circuit that enables the rear auxiliary HVAC control assembly when the front auxiliary blower motor switch is placed in the rear control position.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The auxiliary blower motor is ON while the auxiliary blower motor switches is in the OFF position. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the auxiliary blower motor OFF? | Go to Step 3 | Go to Step 4 |
3 |
Is the auxiliary blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 19 |
4 |
Does the auxiliary blower motor continue to operate? | Go to Step 5 | Go to Step 18 |
5 | Place the rear auxiliary blower motor switch in the OFF position. Does the auxiliary blower motor continue to operate? | Go to Step 6 | Go to Step 13 |
6 |
Does the auxiliary blower motor continue to operate? | Go to Step 7 | Go to Step 19 |
7 | Probe each blower motor control circuit of the rear auxiliary HVAC control assembly with a test lamp that is connected to battery positive voltage. Does the test lamp illuminate when connected to any auxiliary blower motor speed control circuit? | Go to Step 21 | Go to Step 8 |
8 |
Does the auxiliary blower motor continue to operate? | Go to Step 9 | Go to Step 10 |
9 | Test the auxiliary blower motor supply voltage circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 17 |
10 | Probe the auxiliary blower motor low speed control circuit of the auxiliary blower motor resistor assembly with a test lamp that is connected to a good ground. Does the test lamp illuminate? | Go to Step 11 | Go to Step 12 |
11 | Test auxiliary blower motor low speed control circuit between the auxiliary blower motor resistor assembly and the auxiliary low speed blower motor relay for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 15 |
12 | Test auxiliary blower motor medium speed control circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 16 |
Test the auxiliary blower motor switch control circuit between the rear auxiliary HVAC control assembly and the auxiliary HVAC control processor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 14 | |
Test the auxiliary blower motor switch control circuit between the front auxiliary HVAC control assembly and the auxiliary HVAC control processor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 20 | |
15 | Inspect for poor connections at the harness connector of the auxiliary low speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 22 |
16 | Inspect for poor connections at the harness connector of the auxiliary med speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 23 |
17 | Inspect for poor connections at the harness connector of the auxiliary high speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 24 |
18 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 25 |
19 | Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 26 |
20 | Inspect for poor connections at the harness connector of the auxiliary HVAC control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 27 |
21 | Repair the short to ground in the appropriate blower motor control circuit of the rear auxiliary HVAC control assembly. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 28 | -- |
22 | Replace the auxiliary low speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 28 | -- |
23 | Replace the auxiliary med speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 28 | -- |
24 | Replace the auxiliary high speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 28 | -- |
25 | Replace the front auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the repair? | Go to Step 28 | -- |
26 | Replace the rear auxiliary HVAC control assembly. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Rear . Did you complete the repair? | Go to Step 28 | -- |
27 | Replace the auxiliary HVAC control processor. Refer to Auxiliary HVAC Control Processor Replacement . Did you complete the repair? | Go to Step 28 | -- |
28 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The auxiliary blower motor is ON while the auxiliary blower motor switch in the OFF position. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the auxiliary blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the auxiliary blower motor continue to operate? | Go to Step 4 | Go to Step 13 |
4 | Probe each auxiliary blower motor speed control circuit of the auxiliary blower motor switch (auxiliary heat only) or the front auxiliary HVAC control assembly (w/auxiliary heat and A/C) with a test lamp that is connected to battery positive voltage. Does the test lamp illuminate when connected to any auxiliary blower motor speed control circuit? | Go to Step 14 | Go to Step 5 |
5 |
Does the auxiliary blower motor continue to operate? | Go to Step 6 | Go to Step 7 |
6 | Test the auxiliary blower motor supply voltage circuit for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 12 |
7 | Probe the auxiliary blower motor low speed control circuit of the auxiliary blower motor resistor assembly with a test lamp that is connected to a good ground. Does the test lamp illuminate? | Go to Step 8 | Go to Step 9 |
8 | Test auxiliary blower motor low speed control circuit between the auxiliary blower motor resistor assembly and the auxiliary low speed blower motor relay for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 10 |
9 | Test auxiliary blower motor medium speed control circuit between the auxiliary blower motor resistor assembly and the auxiliary med speed blower motor relay for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 11 |
10 | Inspect for poor connections at the harness connector of the auxiliary low speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 15 |
11 | Inspect for poor connections at the harness connector of the auxiliary med speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 16 |
12 | Inspect for poor connections at the harness connector of the auxiliary high speed blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 17 |
13 | Inspect for poor connections at the harness connector of the auxiliary blower motor switch (auxiliary heat only) or front auxiliary HVAC control assembly (w/auxiliary heat and A/C). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 18 |
14 | Repair the short to ground in the appropriate auxiliary blower motor speed control circuit of the auxiliary blower motor switch (auxiliary heat only) or the front auxiliary HVAC control assembly (w/auxiliary heat and A/C). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
15 | Replace the auxiliary low speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 19 | -- |
16 | Replace the auxiliary med speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 19 | -- |
17 | Replace the auxiliary high speed blower motor relay. Refer to Auxiliary Blower Motor Relay Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 19 | -- |
18 | Replace the auxiliary blower motor switch (auxiliary heat only) or the front auxiliary HVAC control assembly (cargo van w/auxiliary heat and A/C). Refer to Auxiliary Blower Motor Switch Replacement or Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the repair? | Go to Step 19 | -- |