The numbers below refer to the step numbers on the diagnostic table.
This step tests for an inoperative auxiliary mode actuator in one mode positions or in the wrong mode positions from the front auxiliary HVAC control module.
This step tests for an inoperative auxiliary mode actuator in one mode positions or in the wrong mode positions from the rear auxiliary HVAC control module.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air does not flow correctly from the auxiliary air distribution outlets. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the auxiliary blower motor OFF? | Go to Step 3 | Go to Blower Motor Always On |
3 | Place the front auxiliary HVAC control assembly blower control in each speed position. Does the auxiliary blower motor operate at all? | Go to Step 4 | Go to Blower Motor Inoperative |
4 | Does the auxiliary blower motor operate correctly for each speed position? | Go to Step 5 | Go to Blower Motor Malfunction |
Does the auxiliary mode actuator drive shaft rotate at all? | Go to Step 6 | Go to Step 8 | |
Does the auxiliary mode actuator drive shaft rotate at all? | Go to Step 7 | Go to Step 12 | |
7 | Test the ignition 3 voltage circuit that is wired between the rear auxiliary HVAC control assembly to the auxiliary HVAC control processor for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 20 |
8 |
Does the auxiliary mode actuator drive shaft rotate at all? | Go to Step 10 | Go to Step 9 |
9 | Test the ignition 3 voltage circuit of the rear auxiliary HVAC control assembly for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 15 |
10 | Test the rear auxiliary mode door control circuit of the rear auxiliary HVAC control assembly for an open, high resistance, a short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 11 |
11 |
Important:: The rear auxiliary HVAC control assembly connector must be connected to correctly perform test.
Does the voltage change from 0 to 12 volts? | Go to Step 21 | Go to Step 23 |
12 | Test the ignition 3 voltage circuit of the front auxiliary HVAC control assembly for an open or a high resistance. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 13 |
13 | Test the auxiliary mode door position signal circuit of the front auxiliary HVAC control assembly for an open, high resistance, a short to ground or short to voltage. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 14 |
14 |
Important:: The front auxiliary HVAC control assembly connector must be connected to correctly perform test.
Does the voltage change between 0 and 12 volts? | Go to Step 21 | Go to Step 22 |
15 | Test the ignition 3 voltage circuit of the auxiliary HVAC control processor for an open or a high resistance. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 16 |
16 | Test the ignition 3 voltage circuit of the auxiliary mode actuator for an open or a high resistance. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 17 |
17 | Test the ground circuit of the auxiliary mode actuator for an open. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 18 |
18 | Test the auxiliary mode door control circuit of the auxiliary mode actuator for an open, high resistance, a short to ground or short to voltage. Refer to Circuit Testing and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 19 |
19 |
Important:: The auxiliary HVAC control processor, front and rear auxiliary HVAC control assembly connectors must be connected to correctly perform test.
Does the voltage change between 0 and 12 volts? | Go to Step 20 | Go to Step 21 |
20 | Inspect for poor connections at the harness connector of the auxiliary mode actuator. Refer to Wiring Repairs and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 24 |
21 | Inspect for poor connections at the harness connector of the auxiliary HVAC control processor. Refer to Wiring Repairs and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 25 |
22 | Inspect for poor connections at the harness connector of the front auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 26 |
23 | Inspect for poor connections at the harness connector of the rear auxiliary HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 28 | Go to Step 27 |
24 | Replace the auxiliary mode actuator. Refer to Auxiliary Mode Valve Actuator Replacement . Did you complete the replacement? | Go to Step 28 | -- |
25 | Replace the auxiliary HVAC control processor. Refer to Auxiliary HVAC Control Processor Replacement . Did you complete the replacement? | Go to Step 28 | -- |
26 | Replace the front auxiliary HVAC control assembly . Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | Go to Step 28 | -- |
27 | Replace the HVAC control assembly - auxiliary rear. Refer to Auxiliary Heater and Air Conditioning Control Replacement - Front . Did you complete the replacement? | Go to Step 28 | -- |
28 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |