Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: This procedure should only be used if the door locks operate with the door lock switches and are inoperative with the remote control door lock transmitter. | ||||
1 | Has the Remote Keyless Entry System Check been performed? | -- | Go to Step 2 | |
2 | Resynchronize the transmitter. Refer to Transmitter Synchronization . Does the transmitter function properly? | -- | Go to Step 3 | |
3 | Inspect the PWR-ACCY fuse 20 at the IP fuse block for an open. Is the fuse open? | -- | Go to Step 9 | Go to Step 4 |
4 |
Is continuity present? | -- | Go to Step 5 | Go to Step 6 |
5 |
Is continuity present? | -- | Go to Step 7 | Go to Step 8 |
6 | Repair the open in CKT 540 (ORN) between the RCDLR connector cavity E and the IP fuse block. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 7 | |
7 | Replace the remote control door lock receiver. Is the repair complete? | -- | -- | |
8 | Repair the open in CKT 150 (BLK) wire between the RCDLR connector cavity N and ground G202. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Replace the fuse. Is the repair complete? | -- | -- |