Removal Procedure


    Object Number: 832908  Size: SH
  1. Remove the intake manifold sight shield. Refer to Upper Intake Manifold Sight Shield Replacement.
  2. Loosen the clamp and separate the air cleaner resonator outlet duct from the mass air flow/intake air temperature (MAF/IAT) sensor assembly.
  3. Loosen the clamp and separate the air cleaner resonator outlet duct from the throttle body assembly.
  4. Disconnect the positive crankcase ventilation (PCV) tube from the outlet duct.
  5. Remove the air cleaner resonator outlet duct.

Installation Procedure


    Object Number: 832908  Size: SH
  1. Install the air cleaner resonator outlet duct to the throttle body assembly and the MAF/IAT sensor assembly.
  2. Connect the PCV tube to the outlet duct.
  3. Caution: Refer to Fastener Caution in the Preface section.

  4. Tighten the clamps at the throttle body assembly and the MAF/IAT sensor assembly.
  5. Tighten the clamps to 5 N·m(44 lb in).

  6. Install the intake manifold sight shield. Refer to Upper Intake Manifold Sight Shield Replacement.