Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant from the system. Refer to
Refrigerant Recovery and Recharging.
- Remove the air cleaner resonator outlet duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement.
- Remove the auxiliary evaporator hose nuts (1) from the main evaporative hose connections.
- Separate auxiliary evaporator hoses (3) and O-rings (2).
- Raise the vehicle. Refer to
Lifting and Jacking the Vehicle.
- Remove the right assist step if necessary. Refer to
Assist Step Replacement.
- Remove the front wheelhouse liner if necessary. Refer to
Wheelhouse Panel Replacement.
- Remove the auxiliary A/C tubes connector nuts (1) from the intermediate connection point.
- Remove the auxiliary A/C tubes clip push pins (1) from vehicle frame locations.
- Remove the auxiliary A/C tubes (2) from vehicle.
- Remove auxiliary A/C tubes clip retaining push pin/bolt (1) if necessary.
- Use a flat-bladed release tool to open retaining clips (2).
- Remove auxiliary A/C tubes from vehicle.
Installation Procedure
Note: The replacement A/C and heater pipes are shipped in front and rear sections.
- Install the auxiliary A/C evaporator tubes (3) to the retaining clips (2).
- Install the auxiliary A/C evaporator tubes (3) to the vehicle.
- Install the auxiliary A/C tubes clip push pins (1) to vehicle frame locations.
- Install new O-rings with replacement auxiliary A/C tubes. Refer to
O-Ring Replacement.
Caution: Refer to Fastener Caution in the Preface section.
Note: Use a adjustable wrench or equivalent holding tool at tube connections to prevent twisting.
Note: Mandatory torque sequence required for proper connections.
- Install the auxiliary A/C tube connection nuts (1) to the intermediate connection point.
Tighten
Tighten the nuts to 16 N·m (12 lb ft).
- Install the right assist step if necessary. Refer to
Assist Step Replacement.
- Lower the vehicle.
- Install new O-rings with replacement auxiliary A/C tubes. Refer to
O-Ring Replacement.
- Install the auxiliary evaporator hose nuts (1) to the main evaporative hose connections.
Tighten
Tighten the nuts to 16 N·m (12 lb ft).
- Install the air cleaner resonator outlet duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement.
- Recharge the refrigerant to the system. Refer to
Refrigerant Recovery and Recharging.
- Leak test the fittings of the component using the
J 39400-A .